3.4.1196/29/2017
QC-CALC SPC - The active Dimension Filter and location and size of windows in a Group are now saved individually for multiple instances of the same file within that Group.

Nikon CMM-Manager - Improved the CMM-Manager driver to handle processing the communication files better when in Poland.

General QC-CALC - Improved the Tools > Options > Update and Help > License Configuration screens to better handle improperly formatted server and port information when connecting to Prolink License Server.

General QC-CALC - Users will now be notified before deactivating a license when the Prolink License Server cannot be contacted.

General QC-CALC - Reduced the default number of Text Factors and Numeric Factors to help reduce file size.

Renishaw Modus, Renishaw Modus Equator & Metris LK Camio (RES files) - Improved the Camio/Modus RES driver to handle double heading lines at the start of pages so features are no longer missed. Also added functionality to control the length of the Tag values to cut down on non-unique Feature Labels.

General QC-CALC - Fixed an issue that caused Sigma Zones and Control Limits to be centered incorrectly.

Reporting - Fixed an issue that could cause a Plot Report to display the incorrect Nominal and Tolerances.

General QC-CALC - Fixed an issue that could cause Notes to show up in incorrect locations when a point was deleted.

QVI Zone3 - Fixed an error that occurred when using Zone3 and collecting a part that spanned multiple communication files.


3.4.1185/31/2017
GOM Precise Industrial 3D Metrology (CSV) - A new interface was added for GOM Precise Industrial 3D Metrology (CSV) .

General QC-CALC - Made improvements to licensing and activation.

Gleason Gear Checker - Updated software location and improved handling of the "SwitchFlankName" variable.

Instron Bluehill - Improved the Instron Bluehill driver to allow sending of Nominal, Upper Spec Limit, and Lower Spec Limit and interpret blank measurements as deleted points.

PC-DMIS 2012 XML Statistics - Improved the PC-DMIS XML driver to collect the radius measurement and also handle null Factor values.

Xspect Open DMIS - Improved the Xspect driver to better handle nominal values of 0.0000.

General QC-CALC - Updated our encryption to be compatible with Windows Platform FIPS on Windows 10.

General QC-CALC - Fixed an issue where changing the language was not prompting the user to restart.

Data Collection - Fixed an issue that would cause the record count to be reset when collecting data from multiple sources.

QC-CALC SPC - Fixed an error that occurred with opening a Group that contained inaccessible QCC files.

General QC-CALC - Fixed an error in licensing when the PLS server and port address had leading or trailing spaces.

Automatic Exporting - Fixed an error that was causing Stat Summary exports to incorrectly report the set path was not found.


3.4.1175/5/2017
QC-CALC Real-Time - Double-clicking a .qcc file will now open QC-CALC Real-Time with that .qcc file open as long as Windows has been configured to do so.

Admin Tool - The Session User name is now displayed in the titlebar if that option is being used in the Part 11 area of the Admin Tool.

Data Collection - The file extensions allowed for a CENP model were expanded to include ".txt" also.

Reporting - Running the Plot Report with more than 500 dimensions now shows a warning and only prints the first 500 dimensions that were chosen. A Windows limitation causes the limit to be 500 dimensions during the processing.

Data Collection - Fixed an issue where QC-CALC Real-Time was reporting that the .qcc file was locked during data collection when more than 60 Numeric or Text Factors were being received in the communication file. Also, Numeric and Text Factor Labels with more than 32 characters are now being collected correctly.

QC-CALC SPC - When using the File > New menu, users are now notified if the .qcc file name they chose already exists. Previously the new file was just created and the old file was lost.

General QC-CALC - The File > Compact Database functionality now completely removes the deleted records from the file in order to decrease the file size.


3.4.1164/26/2017
General QC-CALC - Improved the .NET version detection and messaging when the program first starts.

Reporting - Added a new field to the CFR Part 11 Audit Report so the format of the date within the table can be controlled individually.

Renishaw Modus, Renishaw Modus Equator & Metris LK Camio (RES files) - Improved the Modus RES driver to collect Surface Finish RA and RZ types.
QC-CALC SPC - Improved the detection of the QCC file being available so files QC-CALC Real-Time is writing to no longer appear as "inaccessible" to QC-CALC SPC.

Metrologic Metrolog II - Improved the Metrolog II driver to also collect .CSV files from X4.

GE Close Loop Machining Data (MCL, CLM, DAT) - Changed the GE Lynn HOLD Format name to GE Close Loop Machining Data (MCL, CLM, DAT).
Data Collection - Fixed an issue where extra temporary files were remaining after data collection was complete for some machine types.

QC-CALC SPC - All of the gold font is now removed when undeleting a record. Previously the Factors, Assignable Causes, Corrective Actions, and Date/Time stayed gold.

Renishaw Productivity+ (MPF) - Improved the Productivity+ driver to save the Plus Tolerance, Minus Tolerance, and Nominal values into the correct locations.
Data Collection - Fixed the QC-CALC side of the QC-Gage Save and Continue when a partial part is sent. Previously the individual portions of the same part were not matched up correctly.

Exporting - Fixed a problem where the wrong dimensions were being exported when the Dimensions to Export > Select From List option was used with the "ODBC" Export Type.

Exporting - Fixed an issue where the date of the records and the Fails Count were incorrect in the "SPC Office Buddy" Export Type.

QC-CALC SPC - Fixed an error that appeared when attempting to open a Group when some QCC files within the group were no longer reachable.

Exporting - Improved the "SQL Server (Advanced Format)" Export Type so characters used within commands in SQL are now handled if they are part of a Text Factor.

Keyence IM Series - Changed a default setting so new files being created by the Keyence IM Series driver will have valid .qcc file names.


3.4.1153/15/2017
Zeiss TiMS (CSV Format) - Added a new driver to read the CSV file from TiMS.

GE Lynn HOLD Format - Modified the machine interface to handle other file formats too.

Spartanics M930 - Improved the Spartanics driver so the .qcc file name is now taken from the name of the folder containing the .csv communication file.

Metrologic Metrolog II - Expanded the Metrolog driver to handle additional line formats.

Admin Tool - Options were added to the Admin Tool > Part 11 > Users > Session User area and a new Admin Tool > Switch User menu was also added to enable different Users to log in to the Admin Tool.

QC-CALC Real-Time - The P/T Ratio formula was changed in revision 3.4.100 for the "Single-Part Gage Report (P/T Ratio)" report to handle single-sided tolerances better. This was changed back and a new report variable was added for the new calculation instead.

QC-CALC SPC - The error handling was changed so that errors do not appear unless they remain an error for a few seconds. This makes QC-CALC SPC handle the network disappearing for a brief time much better.

Gage R&R - When using QC-Gage to run a Gage R & R study, QC-CALC no longer automatically opens the corresponding .qcc file.

QC-CALC Real-Time - When the (Trending Features) dynamic Dimension Filter is chosen a trend report will now trigger correctly.

General QC-CALC - Changed the order of operations when the programs load so a new copy of the language file is used every time. This will stop corrupt language files from causing errors to happen.
QC-CALC Real-Time - Extra spaces are now being removed from the Text Factor values that are used in the emails that are sent by the reporting process.

Admin Tool - Fixed the Administrator Tools > Defaults - Data Collection area so the settings now unlock correctly.

QC-CALC SPC - Fixed an error that happened to some .qcc file when using the Edit > Update Fails Count menu.

General QC-CALC - Fixed the Quick Stats panel so the values shown when there is only 1 record are either "N/A" or the Actual value.

QC-CALC Real-Time - Fixed an error that happened if there were multiple Whisker Plots being displayed and a Dimension Filter was enabled that hid dimensions that came before the Whisker Plots.

Manual Input - Fixed an error that was happening in some cases when using the Manual Input functionality.


3.4.1142/16/2017
Zwick CSV Files - Added an interface for the ZWick machine that is completely configurable.

Jenoptik (Hommel-Etamic) EVOVIS surface roughness - Added an interface for the EVOVIS surface roughness/contour software.

PC-DMIS 2012 XML Statistics - Added the "CTN1007" item to the list of items to be collected by the PC-DMIS 2012 XML driver.

Spartanics M930 - Changed the default Source File location for the Spartanics driver.

General QC-CALC - Fixed a problem where UNC paths with a computer name that contained a period were being considered invalid unless an IP addresses was being used.

QVI Zone3 - Fixed a problem where the Remeasure functionality would not work with the Zone3 interface.

QC-CALC SPC - Improved the handling of network outages so that Group files are no longer deleted or have files removed when the network goes down. At the same time a Group > Save menu was added so it is possible to save changes after moving windows around or applying Filters to the files within the Group.

MetLogix M2 & M3 - Fixed an issue that was caused by the 3.4.111 revision when collecting data from the MetLogix M2 or M3 machine.

Metrologic Metrolog II - Fixed an override for the delimiter that was missing for the Metrolog driver.

Data Collection - When a value is received via the Remeasure functionality and it hadn't been received previously, it is no longer shown as a deleted point.

Admin Tool - Fixed the option for Part 11 > Track Creation Entries so you no longer have to reload the User Group in order for the change to be recognized on that computer.

Reporting - The Stat Summary report now displays the same values when the report is run on a single record that it did prior to the 3.4.104 release.


3.4.1131/26/2017
Spartanics M930 - Added a new driver for Spartanics M930.

General QC-CALC - Changed the order in the Quick Stats panel to group Overall Statistics and Within Statistics together. At the same time more Within Statistics were added.

Admin Tool - Fixed a problem where enabling the Automatic Exporting menu in the Menu System Manager also enabled the Secondary Exporting menu at the same time.

Reporting - Fixed a problem caused in revision 3.4.104 where all dimensions that followed a dimension with no variance were also shown as having no variance in the Stat Summary report.

PC-DMIS 2012 XML Statistics - Change the PC-DMIS 2012 XML driver so it now collects a True Position value from the "Deviation" field because the "Measured" field is not sent.

Admin Tool - Fixed a few screens in the Admin Tool area where the locking was not functioning correctly.


3.4.1121/20/2017
LabView with Configure File - Added a new driver for ATE LabView that is completely configurable.

Scott Reducer Test Stand - Added a new interface for the Scott Reducer Test Stand.

Pratt & Whitney Airfoil - Added a new driver for Pratt & Whitney Airfoil.
Nikon CMM-Manager - Added the same ability to populate the Extra Info field for CMM-Manager that already existed for the Feature Labels.

General QC-CALC - The remainder of the "Sigma by R" labels have now been updated to be "Sigma Within".

OGP/QVI MeasureX - Extra carriage returns are now being removed from Factors coming from MeasureX. This takes care of people accidentally hitting the enter key when they were writing the part routine.

Data Collection - Added intelligence to speed up processing for drivers that process the entire file at once instead of line by line.

SPC Reporting - Fixed a problem with the nP Attribute Chart. The wrong value was being used for the Sample Size.

QC-CALC SPC - Fixed a problem that happened when using a Group in QC-CALC SPC with the same .qcc file opened multiple times. When the Group was reopened all instances of the same file were shown directly on top of each other. They are now shown where they were when the Group was closed.

Reporting - Fixed a error that appeared if the user only had Read access to the template location and the setting for Use Windows Default Printer was chosen.

Automatic Reporting - The Automatic Exporting screens now clearly show that the Open in Default Application option is not available for automatic exporting.

QC-CALC SPC - Fixed an error that would happen if a file was open and the network connection was lost.

Next Metrology TouchDMIS - Fixed a bug in the TouchDMIS driver where the correct inspection date was not being picked up.

Reporting - Fixed the "Qty Rejected" field being sent to the MultiPiece First Article report so it now treats bilateral tolerances correctly when the Plus or Minus Tolerance = 0.

Renishaw Modus, Renishaw Modus Equator & Metris LK Camio (RES files) - Made a change so the RES file drivers for Camio and Modus now collect "Profile (Max.)" values regardless of any options that are enabled.


3.4.11112/12/2016
Next Metrology TouchDMIS - Updated the TouchDMIS driver to handle their latest version.

Automatic Reporting - The Use Frequency as Range option is now available for all types of machines and is included in the Tools - Options - Defaults - Auto Report area too.

QC-CALC SPC - Added the ability to control the visibility of the In Control Features, Out Of Spec Features, and Out Of Control Features tabs in QC-CALC SPC. The Menu System Manager in the Admin Tool can be used to disable these new menus too.

Data Collection - Improved all communication file reading so both UTF-8 and UTF-16 file encoding is now handled automatically.

Renishaw Modus, Renishaw Modus Equator & Metris LK Camio (RES files) -The RES file drivers for Camio and Modus now collect "Profile (Max.)" values.

General QC-CALC - Fixed a problem where all Functions used for Calculated Dimensions that use more than a single parameter fail.

Data Collection - Fixed a problem where the "UnprocessedDataFiles" folder would fill up very quickly, especially when running with Zeiss Calypso.

General QC-CALC - Improved the Edit Nominals & Tolerances and Configure True Position areas so the Fails Count is recalculated when changes are made in those areas. The Bonus will now be taken into account when calculating fails for True Position dimensions.

Adcole Gage - Improved the Adcole driver so non-US dates are now handled correctly.


3.4.11011/22/2016
Zeiss Calypso - A new override was added so the Extra Info field can be specified for each dimension.

General QC-CALC - Improved the Help - Gather QC-CALC Information screen.

Hexagon Quindos 7 - A few improvements were made to the Quindos7 driver in order to handle a different file format and collect the Feature Labels and Factors correctly from that format.

QC-CALC Real-Time - Fixed a problem where the Tools - Options - Defaults - File Creation - MultiSource settings were not being validated correctly unless Measure Order or Ask Operator were being used.

QC-CALC SPC - Fixed a problem where the correct filter list was not being displayed at times when the Associate Record Filter with File or Group option was in use.

Gage R & R - Fixed an error that would happen when running a Gage R & R study that was less than 10 Parts, 3 Trials, and 3 Operators.


3.4.10911/11/2016
Data Collection - Improved the error handling in order to help debug data collection issues.

SPC Reporting - Fixed the Range, Max, and Min values being sent to the Histogram report so the values are no longer using a Subgroup Size. This had been changed when the Sigma estimate change was implemented in the 3.4.104 revision.

General QC-CALC - Cleaned up some of the wording and functionality on the Edit Nominals & Tolerances screen.

Renishaw Modus (RES files) - Fixed the Modus RES driver so the Point-Profile feature labels are no longer being trimmed when the inspected value changes from positive to negative.

General QC-CALC - Fixed a problem in the Admin Tool area where the Assignable Cause and Corrective Action settings were not being imported correctly for a User Group.

Nikon CMM-Manager - Improved the CMM-Manager interface so when features sent without tolerances are collected Non-Toleranced (instead of bilateral) features are created within QC-CALC.


3.4.10811/4/2016
Data Collection - Added an override that will copy the full Feature Label being received from the machine into the Extra Info field before the label is shortened to the 32 characters allowed in the .QCC file.

PolyWorks by InnovMetric Software Inc. - Improved the Polyworks driver and added the ability to read more file formats associated with profiles.

Mitutoyo FormPak - Improved the FormPak driver so it will automatically detect the delimiter, adjust for numbers with a different decimal separator, and handle the keywords being in other languages.

Renishaw Productivity+ and Inspection Plus - Improved the driver for Renishaw Productivity+ and added a new interface for Renishaw Inspection Plus.

Reporting - The Custom File Name functionality from Exporting was brought into the Report Settings screen.

Zeiss Calypso - Removed a popup message that was stopping data collection when all 3 .txt files (_CHR, _HDR, and _FET) were not received from Calypso. This message is now displayed in the status area instead.

QC-CALC SPC - Improved the speed in many areas in QC-CALC SPC. Previously the Point Properties area was slow to update when moving the mouse and many things in the Groups area were slow too.

QC-CALC Real-Time - Fixed a problem where Cp and Cpk were being calculated incorrectly when using the "(Trending Features)" Dimension Filter.

Reporting - The Record Numbers being sent to the MultiPiece First Article report were being sent as 0 when there were no Numeric Factors in the .qcc file. This has been fixed.

General QC-CALC - A confirmation screen now appears when attempting to delete an Admin User Group instead of just deleting it without question.

Reporting - Improved the process of running a report to make sure QC-CALC has the proper read/write access to the temporary folder that is used while creating the report.

General QC-CALC - The Ppk, Pp, Cpk, and Cp values were previously not being shown if the data was non-normal. The values are now shown regardless of normality.


3.4.10710/7/2016
QVI Snap-FM - Added QVI Snap-FM to the list of supported machines.

Renishaw Productivity+ - Added a driver for the Renishaw Machine Tool software called Productivity+.

GE VMC Data - Made minor changes to GE VMC Data driver.

Data Collection - Fixed an automation error that was appearing when remeasuring a part.

General QC-CALC - Fixed a few errors that were appearing when using a file containing True Position configurations.


3.4.1069/26/2016
DEK 265 Horizon or Infinity - Updated the install and QC-CALC to use the new DEK licensing.

QC-CALC Real-Time - Factors set to "Off" in the Tools - Options - Factors area are no longer shown in the Factor Values panel and any Factors in that panel using a list are now displaying the list correctly.

General QC-CALC - Fixed a problem where the Theme would be unapplied by going into Tools - Options that was caused in the previous revision.

3.4.1059/22/2016
QC-CALC Real-Time - Added the ability to create simple machine parsers without making a change to the existing code.

GE VMC Data - Added a new interface for GE MCL or GE VMC Data.

QC-CALC Real-Time - An interface was added to control how values that are not within the specification range on Single-Sided features are treated.

Hommel OpticLine - Added an override to allow the delimiter to change for the OpticLine source file.

MetLogix L2 & L3 - Improved the Metlogix L3 driver so it handles DD:MM:SS in the Actual position now.

Data Collection - Added control for where the data is saved when new sources are added to an existing .qcc file.

Zeiss Calypso (4.8.xx or higher) - Added many new Calypso paths that are used during the auto-detect process.
General QC-CALC - Improved the usage and clean up of the memory being used by QC-CALC.

Manual Input - Fixed a problem in the Manual Input screen where Text Factors that were chosen were not remembered or used.

QC-CALC Real-Time - Improved the error handling used when the mouse is moving around the screen.


3.4.1049/7/2016
Zeiss O-Select - Added an interface for Zeiss O-Select.

General QC-CALC - Added settings in the Tools - Options - Statistical Settings area to control which method to use to estimate Sigma, what is the Subgroup Size breakpoint from the RBar method, and if the Unbiasing Constant should be used.

Micro-Vu InSpec for Windows - A setting was added to control what to do when entire parts are received with all points deleted.

Metronics QC5000 - Changed the QC5000 driver so the location of the communication file is no longer used as the location of the .qcc file.

QC-CALC Real-Time - Deleted Points are no longer used in the calculation of trends and an error that appeared when using the Trending Features dynamic Dimension Filter was fixed.

iNOEX Promex Profile Measurement - Fixed iNoex driver so different date formats are now supported.

Data Collection - The Tools - Read Machine Data operation was improved so it now detects if any files are missing before attempting to collect Zeiss Calypso data.

Xspect OpenDMIS - Fixed the OpenDMIS driver so the numbers are read correctly regardless of the number format being used on the machine.

InspecVision Planar - Changed the InspecVision driver so it now handles both "Actual" and "Measured" labels for the data.

QC-CALC SPC - Fixed the Edit - Update Fails Column menu so it no longer pops an error when using Plot View. Also, the Fail Count is now being updated automatically after editing a point value in Plot View.

QC-CALC Real-Time - Stopped an error that was appearing when the network connection was lost.

Hommel OpticLine - The Hommel OpticLine driver was changed to handle blank nominal values.

QC-CALC Real-Time - Fixed an issue where the combination of the path and file name of a .qcc file was causing the file to be reported as not available when it was shown in the File - Open window.


3.4.1038/3/2016
GE GeMoka or ZeissCommand - Added a new interface for GE GeMoka.

Spectro Spark Analyzer Vision - Added a new interface for Spectro.

QC-CALC Real-Time - The GR&R Estimate was improved to use sub-studies when possible as the full study data is being collected.

InspecVision Planar - Improved the InspecVision Planar driver so it handles complex files and also changed the default file type we read to .CSV.

QC-CALC SPC - Fixed a problem where an error was appearing when QC-CALC SPC was launched.

General - The right-click Recalculate Dimensions for Selected Points and Recalculate All Points in View menus used in the graphs in QC-CALC Real-Time and in QC-CALC SPC in Plot View were fixed to handle long calculations better.

Data Collection - Improved collecting data from QC-Gage so commas within Feature Labels, file names, and Factors are now handled better.


3.4.1027/20/2016
Accurex GapGun SPC3d by ThirdDimension - Added a new driver for Accurex GapGun SPC3d.

AMETEK Chatallon CS225 - Added a new driver for the AMETEK Chatallon force measurement machine.

PolyWorks by InnovMetric Software Inc. - Updated Polyworks driver to handle their new output format.

Keyence CSV (deprecated) - The old Keyence CSV driver now appears in the Install Wizard list again so customers that did not upgrade their Keyence software will still run.

QC-CALC Real-Time - The option to allow remeasuring a record to increment the counters for Automatic Reporting and Exporting was expanded to include Remeasures that happen automatically due to a Factor value matching, instead of only applying to the right-click Remeasure Record menu operation.

Hommel Turbo Form & Turbo Wave - Improved the Hommel driver to deal with additional date formats.

Automatic Reporting - Fixed a problem where an automatic report was being triggered incorrectly when the Frequency was set to Once Every Full Display and Only if any records are out of control.

QC-CALC SPC - Made many improvements to better handle the network connection being lost during file operations and also stopped files from being removed from Groups due to the lost network connections.

QC-CALC SPC - Improvements were made so individual files within a Group retain a specific window location and no longer move around based on when they are loaded or other files being removed from the Group.

QC-CALC Real-Time - Fixed a memory leak that could happen when switching files during the data collection process.

Exporting - The Export Data Now and Secondary Exporting operations were exporting an incorrectly formatted file when "Becker Quality Solutions (Bolt Pattern Analysis)" was the specified Export Format to use.

QC-CALC SPC - Improved how the Edit - Lock Editing menu is handled in the Menu System Manager area of the Admin Tool.


3.4.1016/28/2016
QC-CALC Real-Time - An option was added that allows a Remeasure to increment the counters for Automatic Reporting and Exporting.

Zygo MetroScope - Added more intelligence to the Zygo MetroScope driver to watch for repeated Feature Labels.

Ferromatik Milacron - Added a Ferromatik Milacron driver for plastic injection molding.

Hexagon Quindos 6 & 7 - The Quindos 6 & 7 drivers were improved to handle commas in Feature Labels.

QC-CALC Real-Time - Improved the reading of the DataCollectionFrequencyInSecs override so a value that is too large is changed to the maximum value allowed.


3.4.1006/22/2016
Data Collection - Added an override that will make all dimensions have a Nominal value exactly in the middle of the Spec Limits.

Hommel Turbo Form & Turbo Wave - Modified the Hommel Turbo Form driver so it also works with Hommel Turbo Wave (flatness).

General QC-CALC - Added the ability to override the port being used for emailing while still using the Prolink hosted email settings.

Instron Bluehill Tension - Added a new override to the Bluehill driver to allow one program to run multiple times, MultiSource the different runs together, and still create unique Feature Labels.

ASI DataMyte GageMetrics - Added a new driver for ASI DataMyte GageMetrics.

Data Collection - An override was added that can be used to convert any UTF-8 files to ASCII/ANSI before collecting the data from that file.

General QC-CALC - The Tools - Options - Update area has been improved to give control over automatically updating on a schedule and also notify the operator when a new revision of the software is available.

Exporting - An option was added to allow the delimiter to be changed to a pipe when exporting to InfinityQS.

Sterling ProMeasure GageXpress - Added a new driver for Sterling ProMeasure GageXpress.

GageSoft GageMate - Added a new driver for GageSoft GageMate.

GE GENSpect or AeroSpect - Added a new driver for GE GENSpect or AeroSpect.

Data Collection - The Part 11 values from editing a point, deleting a point, deleting a part, Assignable Causes, and Corrective Actions are now saved when being received from QC-Gage.

General QC-CALC - Added an option to control changing the Subgroup Size for any .qcc file. This option can be checked to prevent anyone from changing the Subgroup Size, then locked in the Admin Tool.
QC-CALC Real-Time - The Tools - Options - Data Collection - Actions - Update Nominals and Tolerances area was improved so it now works correctly with the Tools - Options - Defaults - File Creation area and the Admin Tool area.

QC-CALC Real-Time - Fixed an issue that would cause the Displayed Calculation to change back to the default value by going into the Tools - Options screen and clicking OK without making any changes.

QC-CALC Real-Time - Fixed an error that appeared if trying to license on the very first run of the software and it takes too long to finish on the License Configuration screen.

Exporting - Newer versions of Minitab were not opening automatically after the Export finished. This has been fixed.

Data Collection - Improved the error handling when using the MultiSource methods that match up on Factors with Name or Position. You are no longer able to exit that screen without entering a name or position when using one of those methods, a number entered for a position must be between 1 and the maximum number of Factors, and if the Factor name isn't found in the file the Measure Order method will be used for that file instead.

General QC-CALC - The Fail Count is now updated as values are changed manually and counts all Dimensions in the record regardless of what is being displayed or filtered. The Fail Count will not be displayed in the Point Properties window when the Subgroup Size is greater than 1. The Fail Count is also updated when a Remeasure happens now.

QC-CALC Real-Time - The Tools - Options - Factors methods that were available in previous versions of the software have been brought back so that older .qcc files can be used in 3.4 again.

General QC-CALC - Editing a value no longer removes the Deleted flag for that point.

Exporting - Fixed an error that appeared very infrequently when exporting to the Prolink Standard Format with the Export Nominals and Tolerances option enabled with specific .qcc files.

QC-CALC SPC - Fixed the Lock Editing option in the Admin Tool so it can now be both locked to prevent editing and disabled so the operator cannot turn the editing back on again.

QC-CALC SPC - Improved the way the records to use in a report are determined when using a Group. Previously some records would not be used when they should have been.

Reporting - Fixed an issue that caused Calculated and Manual Dimensions to not be added to the reports correctly.

QC-CALC SPC - The Adjust plot height to fit all points option now works in Plot View in QC-CALC SPC like it does in QC-CALC Real-Time.

Admin Tool - It is now possible to enter the Admin Tool area when some paths are unavailable, which allows you to change those paths or files to a new location.

QC-CALC Real-Time - The P/T Ratio formula was fixed in the "Single-Part Gage Report (P/T Ratio)" report to handle single-sided tolerances better.

General QC-CALC - All GR&R reports were changed so the K1, K2, and K3 lookups now use the d2* table properly.

General QC-CALC - The Part 11 file is now deleted when the .qcc file is deleted.


3.4.995/20/2016
General QC-CALC - The Tools - Options - Update functionality was returned to the way it was before the previous revision.


3.4.985/19/2016
Keyence VR G2 - Added an interface to the Keyence VR G2 machine.

Zeiss Calypso - If QC-CALC was unable to delete the remaining _fet.txt and _hdr.txt files during QC-CALC Real-Time starting an error appeared. This has been improved and users are now warned if the files are unable to be deleted and too many remain in the folder.

General QC-CALC - The Tools - Options - Update functionality was improved so there is a clear choice between looking to the website directly or using Prolink License Server to contact the website. Also, you can now set the actual name of the update file when the Local File Server option is used.

Reporting - It is now possible to use the Append Report option while also using the Send in Email option.

QC-CALC Real-Time - Made some improvements to the Help - Quick Settings screen.

Data Collection - The Part Description being sent over from QC-Gage is now being remembered.

Reporting - Fixed an error that appeared when using the Report - Design Template menu to design a Multi-Piece First Article report that contained more than 30 parts.

Exporting - A fix was made so the newer Minitab versions can be launched automatically when exporting.

QC-CALC Real-Time - Fixed a bug that was causing the 1 Sigma Exception trend to not be displayed on the graphs.

Dimension Filters - When editing an existing Containing Text Dimension Filter, you are no longer allowed to save the filter to a name already in use by another filter.

QC-CALC Real-Time - The Send in Email option was not being used even when it was enabled in the Tools - Options - Defaults - Trend Detection area and the default values were being used.

SPC Reporting - Single-Sided tolerances were not being reported correctly in the Report - Cpk - Process Capability screen in QC-CALC SPC. The side of the tolerance that doesn't apply due to the single-sided state is now being reported as "N/A" instead of showing a value that doesn't really apply. This only applies to the first screen that is shown. The final report was reporting the values correctly.

QC-CALC Real-Time - Fixed an error that happened very infrequently when using Trend Analysis and not showing deleted records.

Renishaw Modus, Renishaw Modus Equator & Metris LK Camio (RES files) - Fixed an issue in the RES file drivers for Camio and Modus that happened when a True Position value was sent across. This issue was caused with the 3.4.96 revision.

Reporting - Fixed an error that happened when trying to print to a .pdf file that was still open.

Automatic Exporting - Fixed the Secondary Exporting so the Records Received Since Last Export option now tracks the last record exported via the the secondary export instead of using the primary export value as it was doing.

Data Collection - The override for DataCollectionFrequency is now limited to a maximum of 60 seconds. Entering values higher than that was causing errors previously.


3.4.975/2/2016
Mahr MarSurf M400 - A new interface was added for Mahr MarSurf M400.
BuhlerPrince Pro-Link - Added an interface for BuhlerPrince Pro-Link.
Instron Bluehill Tension - Improved the Bluehill driver to handle the new file examples we now have. Also, overrides were added to use a Factor value as the .qcc file name and to specify Factor values being sent over with the data.

QC-CALC Real-Time - The default value for Center Line Represents in the Trend Detection area was changed so the Saved Mean is used by default.

Metrologic Metrolog II - Improved the Metrolog interface to handle receiving just carriage returns at the end of lines instead of the carriage return/linefeeds that were received previously.

Zygo Metro Pro Report - Improved the Zygo interface so it will now handle the "9.9e+99" actual value that is sent when nothing was measured.

Data Collection - Fixed an issue that caused the persistent list (~~List) method of sending factors to QC-CALC from the inspection machine to fail. This only seemed to happen when using a DBSwitch and only happened occasionally even then.

Hexagon Quindos 7 - BT 4924 - The signs (negative vs. positive) of Actual values were being inverted when the Quindos 7 file did not contain enough detail. This has been fixed.

Reporting - Fixed an issue that happened when trying to email a report, but the path specified for the file to email didn't exist.

Hommel OpticLine - Changed the Hommel OpticLine driver so the .qcc file is now saved to the correct location instead of being saved to the location of the communication file.


3.4.963/31/2016
Renishaw Modus, Renishaw Modus Equator & Metris LK Camio (RES files) - Fixed the right-click Remeasure so it should now work correctly for these models.

3.4.953/30/2016
Exporting - Two new exporting formats were added for WinSPC: WinSPC (File Export Only - Specifications) and WinSPC (File Export Only - Data).

Xspect OpenDMIS - An option was added for the Xspect OpenDMIS driver so the Feature Labels will not change if dimensions are inserted in the file or there is a True Position feature with the Bonus included (which was part of the label).

QC-CALC SPC - The logging of errors and settings changes was improved so the log files won't get too large.

QVI Zone3 - Added the PARTEND functionality to the Zone3 driver so there is now a way to manually signal to QC-CALC where one part ends and the next one begins. The automatic method was failing in that regard for Repeats and Continuous Run.

Instron Bluehill Tension - Changes were made to the Instron Bluehill driver to support "Bluehill 3" and the "Bluehill_FindFactorsInDataRow" override now looks for factors in data rows.

Exporting - Added WinSPC version tracking and updated for the latest version (8.2) for the WinSPC export. At the same time the Archive object was removed since it is apparently no longer used.

Reporting - A new field (Records_per_Dimension) was added to the Stat Summary report to show how many records per dimension were used in the calculations. Deleted points will cause some dimensions to use more records than others.

Admin Tool - A few checkable menus were found to not be checkable in the Menu System Manager in the Admin Tool area. This has been fixed.

Data Collection - The ability to track Creation Entries for Part 11 that was added in revision 3.4.85 is now off by default. This should make QC-CALC run the same way it did before an update for anyone using the Part 11 functionality.

Reporting - The Number_of_Records variable in the Visual Part Report was always being sent as 0. This has been fixed.

QC-CALC Real-Time - Fixed an issue that was happening when the program loaded and the part rate value being calculated was too large.

QC-CALC SPC - The Number_of_Points value in the Other Reports - Plot Report was not showing the correct value at times if a Record Filter was applied.

Exporting - Updated the Net-Inspect Export so it is checking the count of features exported vs. the number of features not deleted. Our count now accurately reflects the number of features after deleted features have been removed.

Metris LK Camio (RES files), Renishaw Modus (RES files) & Renishaw Modus Equator (RES files) - Improvements were made to the RES file driver to handle short lines within the file.

Reporting - The Raw Data report was not matching the results in the QC-CALC Real-Time screen when the SingleSidedLowerEffectsPlotColor override was in use. This has been fixed.

Record Filtering - Fixed an issue in QC-CALC SPC where the Factor columns being used by the Record Filtering were not updating when a different .qcc file was opened.

Exporting - The ASCII User Defined Template export was changed so you can no longer choose items that are not available for the particular template line being edited.


3.4.943/3/2016
QC-CALC SPC - Fixed an issue in the 3.4.93 revision only that caused problems when using a Subgroup Size greater than 1 and Dimension Filters in the Plot View screen.


3.4.933/2/2016
Zygo Metro Pro Report - A new interface was added for Zygo Metro Pro Report.
Werth Compact Report - A new interface was added for Werth Compact Report.
Marposs Gage - 3 options were added for setting the item order in a data line, applying a magnitude change, and treating the Actual as a Deviation.

Reporting - The Plot Report graphs now follow the Plot Height Settings the main QC-CALC Real-Time screen is using.

General QC-CALC - Fixed an issue that happened when using the Dimension Filtering Containing Text functionality and using a name that had already been used.

Gage R & R - The Gage R & R - Remeasure menu has been removed since the right-click Remeasure menu covers this functionality.

QC-CALC Real-Time - Fixed an error that appeared when Adapting a file that contained Calculated Dimensions.


3.4.922/3/2016
QC-CALC SPC - Fixed an error that appeared with some .qcc files when opening in Grid View or switching from Plot View to Grid View.

Admin Tool - The Menu System Manager was fixed so the correct items are disabled and checked or not checked when they should be.

QC-CALC Real-Time - The new Update Nominals and Tolerances area in the Data Collection - Actions and Defaults - Data Collection areas now work correctly with the Admin Tool and each other. At the same time the new options were made to work.


3.4.911/22/2016
QC-CALC Real-Time - A new Quick Settings menu was added to the Help menu in order to help with troubleshooting issues while on the phone.

Mitutoyo MCOSMOS Prolink Standard - A new driver was added for MCOSMOS that uses a different format that the standard MCOSMOS output.

Keyence IM Series - Improved the Keyence IM Series names to clear up confusion between the RS232 and CSV file drivers.

Instron Bluehill Tension - Improved the Bluehill driver.
DEK 265 Horizon or Infinity - Changed the source File Path and Name used for DEK machines to match the location of the Readings.DEK files used by newer versions of the DEK software.

Data Collection - The Pass-Through file no longer has a path included that redirects where the .qcc file is stored.

Xspect OpenDMIS - Fixed the Xspect OpenDMIS interface so it now collects angle measurements sent with a degrees:minutes:seconds format. Also, a second driver that didn't create Feature Labels was removed.

Admin Tool - Fixed an issue where it was possible to lock the Pause Data Collection menu in the Paused mode via the Admin Tool.

QC-CALC SPC - Fixed an error that happened when using Other Reports in QC-CALC SPC with a Group that contains files with an uneven number of records.

General QC-CALC - The Tools - Password Protection menu option was no longer working.
Admin Tool - Fixed a problem where some local settings were ending up being saved as Admin settings when changing a User Group.
Exporting - The manual Export to SPC Office Buddy option was not remembering the name of the Excel Job that had been chosen.

Exporting - Some Automatic Exporting Defaults were not being used for new files when in SmartReport mode.

Reporting - The Plot Report now shows all points even if there is only one point available to display.

Admin Tool - The checked state of checkable menus is now being set correctly when disabling menus in the Menu System Manager.

QC-CALC SPC - Fixed a problem with the graphs in the reports in QC-CALC SPC where the numbers being shown on the axis were whole numbers instead of using the precision for the dimension.

General QC-CALC - Fixed an issue that was causing the Calculated Dimension values to not be sent to SQL with the rest of the data when using EDL.


3.4.9012/16/2015
General QC-CALC - Non-US date formats were causing the Help - Run Update menu operation to fail. This has been fixed.
QC-CALC SPC - Fixed an error that appeared when trying to email a report from QC-CALC SPC and a Group of data files was in use.
QVI Vici MTL - Improved the Vici MTL driver to handle extra commas in the output file.

3.4.8912/8/2015
QC-CALC Real-Time - The background colors of a Whisker Plot will now change if the whiskers go out of Control or Spec instead of just being based on the Average portion of the graph.

Troubleshooter - Improved the Troubleshooter program so it now gathers hidden files, picks up the files from the Source File Backup area better, only gathers the Admin files from the Admin folder, and no longer shows an error when too many files are gathered.

General QC-CALC - You are now prompted for a password when connecting to or disconnecting from the Admin Tool. This will happen even if the Keep me logged in option had been checked on the Log In screen.

QC-CALC SPC - Fixed the right-mouse click functionality in the Grid View in QC-CALC SPC. This had been broken by changes in the 3.4.88 revision.

General QC-CALC - The new "WorstCase" calculation is now based on the percentage of the tolerances used so that non-symmetrical tolerances are handled better.


3.4.8811/23/2015
QVI Vici MTL - Improved the Vici interface to handle new file formats that are generated in Europe.
General QC-CALC - Added an new calculation type to the Calculated Dimensions that returns the actual furthest away from the nominal value for the dimensions specified.

QC-CALC SPC - Factor values for the first record being used in the report are now being sent to the Cpk - Process Capability report.

Data Collection - Fixed a problem that was causing the Text Factor having the following name method to not be used again when that was the chosen MultiSource Record Merge Method.

General QC-CALC - Improved how a missing or not accessible filter file is handled.
General QC-CALC - When the Subgroup Size is greater than 1 and changes are made to a Factor value that change will now apply to the entire subgroup.

QC-CALC SPC - QC-CALC SPC was improved to handle really large monitors better.
Exporting - The File Name validation no longer views Custom Names as invalid.
General QC-CALC - Fixed an error that occurred when using the File - Modify Database Structure menu.
QC-CALC SPC - Improved the error handling when QC-CALC SPC loses connection to the network locations necessary to run.

PC-DMIS 2012 DataPage Stats XML - Fixed a problem that was causing Feature Labels to appear as ": :" in some cases for the PC-DMIS DataPage XML driver.

Metris LK Camio (RES files) - Improved the LK Camio RES driver to handle headers with multiple items better. Also removed _Mn from the Profile label.


3.4.8711/10/2015
Renishaw Machine Tool Probes (DPRINT Output) - Added an interface for the Renishaw Machine Tool Probes output for the DPRINT command.

Exporting - A new export format was added for Chrysler CMDANA CMM Data Format (C3DF).
Zeiss Calypso - Improved the detecting of Calypso on a computer and the default data source location.
Data Collection - Improved the control of the Update Nominals and Tolerances options.
Data Collection - The Dimension Source and Extra Info fields are now available in the Update Nominals and Tolerances area so new values being received in the communcation files can be used.

General QC-CALC - Improved the Point Properties panel when the Subgroup Size is greater than 1 so any changes made to Factors now apply to all points within the Subgroup.

Data Collection - Fixed a problem that happened if more than 30 Text or Numeric Factors were sent in from the inspection software and the database did not have enough room to store them.

QC-CALC SPC - Occasionally QC-CALC SPC would not close correctly and upon restart it would be stuck in a recovery loop the next time the program was started. This has been fixed.


3.4.8610/23/2015
Mahr MarWin - Added a override for the MahrWin driver so features that begin with "taper" can have their values saved as absolute value. At the same time the path being received with the file name is no longer used as the location to save the .qcc file.

Keyence IM Format - A new option was added for the Keyence IM Format so the value found on an MS line is now used as the .qcc file name.

QC-CALC Real-Time - The interface used to create lists of values for Automatic Factors has been improved.
Data Collection - A hidden option to not use the path being collected in the communication file from the inspection machine as the location to save the .qcc file was added.

Data Collection - Fixed an issue that stopped data from being collected when using QC-Gage 3.3 along with QC-CALC Real-Time 3.4.

General QC-CALC - We now attempt to detect if the program is not visible on the screen and center it on the main screen if it is found to not be visible with the previous settings.


3.4.8510/8/2015
Microvision Instruments - Filtrex - Added a new interface for Microvision Instruments - Filtrex.
Keyence XM Format - Added a new Keyence XM Format driver.
KOMO Router (CSV Output) - Added a new interface for the KOMO Router.
QC-CALC Real-Time - Fixed a problem that was causing a leftover graph to remain on the screen when using the Synchronize QC-CALC with the currently running spec plan option within QC-Gage.

Renishaw Modus, Metris LK Camio (RES files) - Improved reading the header section of the communication files (RES) to handle all the different formats being received.

Data Collection - Improved the message that appears when adapting the file fails due to duplicate Feature Labels. Also added a new utility to help find those duplicate Feature Labels.

General QC-CALC - The Part 11 functionality was greatly improved.
QC-CALC Real-Time - A warning is now displayed if the Source File Path and Name is changed to a network location since that behavior is not recommend.

General QC-CALC - It is now possible to delete a User Group in the Administrative Tools area.
General QC-CALC - Improved the error message that appears when the template being used for the Raw Data report has variables and fields in it that are no longer understood by this version of QC-CALC.

IMS Virtual DMIS VMS - Adapted to handle a different label being sent for a Diameter from IMS Virtual DMIS.
QC-CALC Standard Format (Pipe Delimited) - Improved the interface so capitalization and spacing will no longer impact Factor values being collected.

QVI Zone3 - Extra spaces are no longer collected with the Text Factors coming from QVI Zone 3.
QC-CALC SPC - Improved the messages in the Bottom Status Bar for both Record and Dimension Label Sorting.

Data Collection - Fixed an issue where the Feature Label would update when new data was collected even if the Prevent Nominal Update option was enabled for that dimension.

QC-CALC SPC - Increased the precision of the numbers shown on the Y-axis of the Individual & Moving Range chart so the numbers will now line up correctly with the lines within the chart.

QC-CALC SPC - The Part 11 challenge was happening within QC-CALC SPC when the CFR Part 11 Audit Report was run regardless of where the output was going. The challenge will now only appear if you are printing to a signed PDF report.

QC-CALC SPC - Fixed an error that was appearing if the SPC_Monitor_Timer_Interval value was changed using QC-Config to a value greater then 32.

General QC-CALC - Changed the default Text Factor Width to the maximum 50 characters allowed. This should help with Text Factor values being cut off at 20 characters for all new files that are created.

Exporting - Fixed a couple of small exporting issues with the SQL Server (Advanced Format). Situations where there were no factors in the .qcc file were not being handled correctly.

Data Collection - It was possible to replace previously collected data without the Part 11 challenge happening if the MultiSource merge method found a matching entry for new data being collected. This is no longer possible.

Zeiss Calypso - The automatic Source File Backup was not happening for the Zeiss Calypso models.
Data Collection - Fixed an error that happened during data collection when Manual or Calculated dimensions were not at the end of the list of dimensions.

QC-CALC Real-Time - Fixed an issue caused by Trend Detection trying to detect trends in the wrong features.
Data Collection - It is now possible to use the ~~list method of passing Factor values in to QC-CALC along with a PartBreak. Previously the list items weren't being used for any PartBreak sections within the initial part.


3.4.848/28/2015
General QC-CALC - An interface was added in the Edit Nominals and Tolerances screen to control the pictures used for the dimensions.

Data Collection - Fixed a problem that was causing the Text Factor having the following name method to not be used when that was the chosen MultiSource Record Merge Method.

Data Collection - Fixed the Automatic Numeric and Text Factors in the Tools - Options - Factors area so they can now be used.

Record Filtering - [ ] are no longer allowed to be used in the names of Record Filters.
Manual Input - Messages were improved in the Manual Input screen so operators will now be aware that they are missing some or all of the values that were supposed to be entered.

QC-CALC Real-Time - The Tools - Options screen will now open even if there isn't a printer loaded on that computer.

General QC-CALC - Fixed an error that appeared when using large values in Numeric Factors while also sending the data to EDL.

Nikon CMM-Manager - Made a slight adjustment to the CMM-Manager interface.

3.4.838/11/2015
Starrett KineMic - Added a new interface for the Starrett KineMic machine.
Komo Router - Added a new interface for the Komo Router machine.
Exporting - The Dimension Source and Dimension Information fields are now available in the ASCII User Definied Template export.

General QC-CALC - Range Charts can now be controlled across all files instead of having to be set for each specific file or dimension within the file.

Exporting - An option was added to control what is sent to Excel when a Deleted Point is exported.
QC-CALC Real-Time - A new Trend was added that will trigger if the specified number of identical values are received in a row.

Marposs Gage - Added an override to adjust the magnitude of the tolerances. Also, all header values are now collected as Text Factors.

Metris LK Camio, LK-DMIS, & Renishaw Modus - An override was added to control removing the date from the source file name.

Reporting - The Design Template buttons within the various Reporting screens are now enabled or disabled to match the setting in the Menu System Manager within the Admin Tool.

Exporting - The ODBC export is no longer limited to 200 dimensions as it was previously.
QC-CALC Real-Time - Fixed a problem where the titlebar of QC-CALC Real-Time was starting off the screen when running on lower resolution monitors.

Data Collection - Fixed an error that appeared if QC-CALC Real-Time was minimized when new data was received.

Exporting - Fixed a problem that caused the Automatic Exporting to not happen if there was a Calculated Dimension in the file.

QC-CALC SPC - Fixed an error that happened when the user logged out of Windows while QC-CALC SPC was still running.

Marposs Gage & Gage E9066 - Added an override for both drivers to specify the format of the line being read.

Zeiss ACCTee Pro (SurfCom) - Fixed an issue in the Zeiss ACCTee Pro (SurfCom) that was caused by an incorrect variable in the driver.


3.4.827/28/2015
General QC-CALC - Fixed an error that appeared when using the Calculation Editor with the Windows > Display setting set to anything higher than "Smaller" (100%).

Reporting - Fixed an error that appeared when running a report on a file with True Positions configured that didn't have any columns available for Assignable Causes or Corrective Actions.


3.4.816/26/2015
General QC-CALC - An interface was added so updates can now be downloaded by using the connection to Prolink License Server or the Prolink website. The new functionality also shows a link when a new update is available and shows you a list of the changes between the revision currently in use and the new revision.


3.4.806/11/2015
Klingelnberg Gear Analyzer - Added an interface for the Klingelnberg Gear Analyzer.
Marposs Gage & Gage E9066 - Added the ability to specify the exact format of the data line for the Marposs interfaces.

Exporting - Added a new Q-DAS DFQ export format that allows an existing file to have additional data appended to the bottom of the file.

General QC-CALC - When the Range charts are enabled the sigma lines are now shown if they were being shown on the XBar chart.

QC-CALC Real-Time - The following changes were made to the Assignable Cause/Corrective Action area: It was separated from the Trend Analysis area (enabling the Tools - Trend Analysis menu is no longer required). The operator can now be prompted to enter an Assignable Cause/Corrective when a Trend occurs. A Subgroup Size of 1 is no longer required. Options are now available to disregard any Record or Dimension Filters when using this functionality.

Zeiss Calypso (4.8.xx or higher) - Changes were made to handle detecting newer versions of Calypso being installed on the computer and the new output location in Public Documents is now being used by default.

Zeiss ACCTee Pro (SurfCom) - Fixed a problem in the Zeiss ACCTee Pro (SurfCom) interface that was causing records after the first record to not be received correctly.


3.4.796/8/2015
General QC-CALC - Improved the Assignable Cause/Corrective Action functionality so "None" can no longer be entered as a Reference value. "None" is a reserved word and causes major issues the next time the program starts if it is entered.

Exporting - Improved the speed of Automatic and Manual Exporting to Excel.
Dimension Filtering - You are no longer allowed to save a Dimension Filter without entering a name.
General QC-CALC - Fixed an error that happened in Switzerland that was caused by number format differences.
QC-CALC Real-Time - Changed the message that appears when choosing to Save Calculated Limits from the Tools menu so it reflects the operation that will actually happen.


3.4.785/26/2015
MetLogix L2 & L3 - Added the MetLogix L2 & L3 driver.
Metris LK Camio (RES files) - Added an option to remove the date from the file name when collecting data.

3.4.775/4/2015
Exporting - Changed the comparison method being used to determine if the upper and lower control limits have changed when exporting to SQL Server. Previously numbers that cannot be represented in binary were causing new models to be saved in the SQL database even though those numbers hadn't actually changed.

Data Collection - New dimensions being added to a database may not have been receiving the correct nominals and tolerances depending on the settings in the Tools - Options - Data Collection - Actions - Update Nominals and Tolerances area. New dimensions will now always use the nominals and tolerances from the source file.


3.4.764/16/2015
PC-DMIS 2012 XML Statistics & DataPage Stats XMLS - Added override options for PCDMISXMLStatsMinMaxOption and PCDMISDatapageXMLStatsMinMaxOption.

PC-DMIS 2012 XML Statistics - Improved PC-DMIS XML driver to include form tolerances and several other characteristics that were not previously included.

Admin Tool - Fixed issue with eSign certificate files having to be re-certified after password change

3.4.754/6/2015
Metlogix M2 & M3 - Updated the Metlogix M3 driver to keep it current with the changes in version 2.0 of M3. Specifically the ability to add prompts and traceability, the file format changing from ASCII to Unicode, and inspection routine specific export settings.

Zeiss Calypso - Fixed the override that specifies a field in the Calypso communication file to use for the Dimension Source so people not using the option will no longer see errors.


3.4.744/1/2015
Zeiss Calypso - Added an override that specifies a field in the Calypso communication file to use for the Dimension Source.
LK CMM using LK-DMIS, Metris LK Camio, Renishaw Modus, Renishaw Modus Equator - Added the ability to collect degrees/min/sec through the RES file.
Approve for DeMeet Multi-sensor - The database name is now remembered on a multiple part communication file and all factors are being collected.
Exporting - Fixed a problem where the Open in Default Application option on the Export - Export Data screen was disabled when it shouldn't have been.

MetLogix M2 & M3 - Updated the Metlogix driver to handle the Unicode file format now being sent.
Valisys by Tecnomatix (DML Output) - Fixed a small issue with the ValisysSetup.txt to trim the feature type.

3.4.733/30/2015
Etamic Gages CMZ32 & CMZ16 - Added an override so the Etamic driver assumes values are Deviations instead of actuals.
Mitutoyo Formpak - Fixed the Formpak driver to handle the latest format from Mitutoyo.
General QC-CALC - QC-CALC has been fully translated into Chinese, French, German, Italian, Spanish, and Swedish.
Reporting - The Report Designer will now appear in the language QC-CALC is using instead of always appearing in English.
Metlogix M2/M3 - Removed an extra path from the Metlogix M2/M3 driver.
Manual Input - Finished many major changes to make the Manual Input Screen function better.

3.4.723/19/2015
iNOEX Promex Profile - Added a new interface for iNOEX Promex Profile.
QVI Snap-X - Added an interface for the QVI Snap-X software.
Data Collection - The right-click Remeasure Record functionality was improved so all methods of data collection can now use it.
Keyence IM Series - The Keyence drivers were cleaned up to prevent confusion. There are now just 2 drivers available: RS232 and the CSV file method.

Mitutoyo Roundpak - Fixed the Roundpak driver to handle the latest format from Mitutoyo.
Exporting - The Prolink XML export would mark the wrong point as deleted if a Dimension Filter was applied.
QC-CALC SPC - Fixed a problem that was causing the Record and Dimension Filters to be disabled if a QC-CALC SPC LITE license was in use.

MicroVu InSpec - Fixed a problem that was caused with the 3.4.64 revision. QCC files will now be save to the location specified in the Tools - Options - Data Collection - Set Paths - Location to save new data area.

Approve for DeMeet Multi-sensor - Fixed a problem that was caused with the 3.4.64 revision. QCC files will now be save to the location specified in the Tools - Options - Data Collection - Set Paths - Location to save new data area.


3.4.713/4/2015
PC-DMIS 2012 XML Statistics - Added an option to create Feature Labels based on different elements received from the PC-DMIS XML output.

PC-DMIS 4.0+ by Wilcox Associates - Added an option to create Feature Labels based on different elements received from PC-DMIS.
QC-CALC Real-Time - The Tools - Options - Data Collection - Actions - Update Nominals option was improved to give control over updating Nominals, Tolerances, Feature Labels, or Precision explicitly. You can also make this setting work for the next part received only so it shuts off again after a part is received.

Approve by DeMeet - Improved the DeMeet driver so the QCC file name is created that is based on the .CSV file name.
Nikon CMM-Manager - Modified the CMM Manager driver to pick up a couple Surface Profile cases that were not handled previously.
QC-CALC SPC - Fixed an issue where an error occurred when using Monitoring over a wireless connection.
QC-CALC Real-Time - Improved the Help - Install Wizard screen to clear up some confusion people were experiencing.
Metris LK Camio (CSV files) - Fixed the Camio CSV driver so the True Position values are now picked up correctly.
QC-CALC SPC - Fixed an error that appeared when canceling the Group - New process and a partial file was created.
General QC-CALC - Changes were made to handle the Windows XP operating system differently than Windows 7 or 8. This should fix many issues that XP users were seeing.


3.4.702/13/2015
Zeiss Calypso - Changed the Calypso driver so True Position dimensions are created as non-toleranced instead of using the 999.000 values for the upper and lower tolerances that are received in the file.

Next Metrology TouchDMIS - The Next Metrology TouchDMIS software is now automatically detected by QC-CALC Real-Time.
FARO CAM2 MeasureX, MeasureX (Text Output), and CAM2 Q - Changed the default data collection path of the Faro interfaces to the c:\SPCData location. The previously used locations were typically locked by IT.

QC-CALC Real-Time - Fixed an error that appeared when attempting to download machine specific files from the website via the Help - Machine Specific menu.

QC-CALC SPC - Fixed an error that happened when using the X to close a file within Group instead of editing the Group to remove the file.
General QC-CALC - Changed some areas of the code to make sure the Chinese, Russian, and Polish characters are displayed correctly.
QC-CALC Real-Time - QC-CALC Real-Time was improved to handle really large monitors better.
QC-CALC Real-Time - The View - Configure True Position area was improved to give more control over the sizing of the columns to make items more readable.

Exporting - The Q-DAS Type-2 GR&R and Q-DAS Type-2A GR&R Export Types were removed from the Exporting area. These were no longer being used.

General QC-CALC - Improvements were made on the Assigning a Cause/Corrective Action screen so the Dimension Labels are always readable.


3.4.692/10/2015
Data Collection - A new, automatic source file backup method was added so the main Tools - Options - Data Collection - Set Paths - Source File Backup option can be moved to a network location safely.

Admin Tool - A few options pertaining to passwords were cleaned up in the Administrative Tools area. The Reset Password menu was removed since the Change Password menu functionality does the same thing. The Deactivate Account setting can now be done on a user by user basis. The Password Expiration setting can now be done across all users instead of only on individual users.

Exporting - Cleaned up the check boxes at the bottom of the Export Data screen so they are enabled and disabled for each Export Type as they were in 3.3.

Exporting - The Specified Range option is no longer available in the Export Data screen if a Record Filter is applied.

3.4.682/6/2015
Keyence IM Format - Added and improved the Keyence IM Format interface.
Twin Coast Metrology, Surface Gage - Added an interface to Twin Coast Metrology, Surface Gage.
Next Metrology Touch DMIS - Added the Next Metrology TouchDMIS interface.
Reporting - Made a change so previously selected printer information is forgotten if the option to use the Windows default printer is chosen.
General QC-CALC - Fixed a problem in some areas with displaying different characters sets (characters from other languages).

3.4.672/4/2015
General QC-CALC - Added the ability to lock down Adding/Editing/Deleting of Record and Dimension Filters.
Renishaw Modus and Metris LK Camio (RES files) - Added the PATHSWITCH functionality to both the Renishaw Modus (RES files) and Metris LK Camio (RES files) drivers.

General QC-CALC - More messages were changed through out the program.
SmartReport - Fixed an issue where the Tools - Options - Defaults - Auto Report - Print To... - File option was not being used when new .qcc files were created during SmartReport data collection.

General QC-CALC - Using the Kill License button on a QC-CALC Enterprise copy now removes the license for both QC-CALC Real-Time and QC-CALC SPC.

QC-CALC SPC - It now takes a single restart of QC-CALC SPC to change the language being displayed instead of needing two restarts for the change to occur.


3.4.661/28/2015
Aberlink 3D Mk3 - Added an interface to Aberlink 3D Mk3 CMM software.
General QC-CALC - Added options to lock Adding or Editing/Deleting Record or Dimension Filters.
QC-CALC SPC - Fixed an error that happened if a Dimension Filter was causing some dimensions to not be shown before a True Position graph.
Data Collection - Fixed a problem that happened with MultiSource files using Measure order when not all dimensions were being received within a source for each record.

General QC-CALC - The Quick Stats area is no longer limited to 100 points. This means if more than 100 records are shown in the graphs all records displayed will be used for the statistics within the Quick Stats area.

Exporting - The Assignable Causes and Corrective Actions will now be exported in the ASCII Text File Export.

3.4.651/14/2015
General QC-CALC - The screen used for generating Factor Lists was improved.
Reporting - Fixed an issue in the Raw Data Report where deleted points were being replaced by zero and the zeros were being used in calculations.

Data Collection - The Ask Operator choice for the Tools - Options - Data Collection - Actions - If number of machine dimensions... choice will now trigger the question for the operator if less dimensions were received instead of just if more dimensions were received.

Exporting - Fixed an error that happened when exporting to Q-DAS with the Define Out of Spec as an Invalid Measurement (K0002 290) option checked and a value is Out of Specification.
QC-CALC Real-Time - The Tools - Options - Data Collection - Data Source Information - File Information area was improved so the File Path and Name area is used for both regular data collection machine types files or for the Q-DAS format files.

QC-CALC Real-Time - The Automatic Reporting and Exporting counters are no longer reset after leaving the Tools - Options screen.
General QC-CALC - Fixed a problem that was causing an error to appear on some computers when the Help - Run Update menu was used.

3.4.641/6/2015
Nikon CMM Manager - Changed the Nikon CMM Manager driver so it now reads Profile output when compared against a CAD file.
General QC-CALC - Additional controls are now available to give you the ability to see data points that are too high or low to appear on the graph in the default view.

General QC-CALC - Changed the files used for all languages so the same files can be used for all Prolink products.
SmartReport - The Table Name area is no longer disabled for Automatic Exporting if the Tools - SmartReport menu is enabled.
SmartReport - The Enable Append Report option is now available for Automatic Reporting if the Tools - SmartReport menu is enabled.

QC-CALC Real-Time - Fixed a problem that caused blank plots to be displayed when the dimension was Non-Toleranced and the Actual(s) equaled the Nominal value.

MicroVu InSpec - Fixed the MicroVu InSpec driver so Labels ending with "_X" are no longer changed.
QC-CALC Real-Time - Fixed an error that appeared in QC-CALC Real-Time when using the Synchronize QC-Calc with the currently running spec plan in QC-Gage.

QC-CALC Real-Time - Fixed an issue where the True Position Bonus value was exceeding the maximum allowable bonus value.
Exporting - Fixed a problem where the value entered for the Newest Records in File option on the Manual Exporting screen would not change correctly.

Data Collection - Cleaned up the Tools - Options - Data Collection - Set Paths - Location to Save New Data area in order to limit the choices available and stop some confusion a few of the settings were causing.

QC-CALC SPC - Fixed an incorrect message appearing in the title of QC-CALC SPC.
QC-CALC Real-Time - The menus to enable Trend Detection and the Manual Input Screen are now controlled correctly by the Administrative Tool.

QC-CALC SPC - Fixed a problem that existed in revisions 62 and 63 where the Monitoring was failing.
General QC-CALC - Fixed an error that happened when running the first time after installation if the Prolink.xml file ended up empty.

3.4.6312/10/2014
MicroVu InSpec - Improved the MicroVu interface so it handles all the different output formats we've received to date.
Nikon CMM-Manager - Added an option to create Feature Labels based on different elements received from CMM-Manager.
Medisize LabVIEW ATE v2 - An interface was added for version 2 of Medisize LabView ATE.
General QC-CALC - The Help - Gather QC-CALC Information menu functionality was improved to handle duplicate files better.

3.4.6212/8/2014
Toshulin Machine Tool - Added the Toshulin Machine Tool driver interface.
SmartReport - The Automatic Reporting and Exporting screens now have some settings disabled because these Items are received in the communication files for SmartReport.

Keyence CSV - Added two overrides for the Keyence CSV interface: 1) Use CSV file name as QCC name and 2) Calculate Nominal from incoming USL and LSL.

General QC-CALC - All areas of QC-CALC should now be able to handle more than the default 30 Text and 30 Numeric Factors.
Exporting - The Configure button now works for the Zontec Synergy 2000 export and the files created by the export are created in the location specified.

Data Collection - Fixed a problem where files with multiple sources and persistent Factors were not working correctly.
QC-CALC Real-Time - Fixed a couple settings that were being translated into other languages in the INI files. This caused problems if the language setting was change after these settings had been saved in the previous language.

General QC-CALC - Fixed the spacing in some messages through out the program.
QC-CALC Real-Time - Using the File - Show QC-CALC SPC menu (or the corresponding toolbar button) within QC-CALC Real-Time will now launch QC-CALC SPC with the same .qcc file open that QC-CALC Real-Time was displaying.

QC-CALC SPC - Stopped an error from appearing when changing Record Filters in QC-CALC SPC when the Record Filter file is located on the network and the network connection is no longer available.

QC-CALC Real-Time - Fixed a problem where the scrollbar wasn't moving to match the data being shown in the graphs when the View - Add Range Charts menu was used.

QC-CALC Real-Time - Fixed a problem where non-English characters in Feature Labels were not being displayed correctly in the graphs or the Top Status Bar in QC-CALC Real-Time.


3.4.6111/19/2014
QC-CALC Real-Time - Fixed an error that appeared if you cancelled during a File - Merge operation.
Nikon CMM-Manager - Added an option to create Feature Labels based on different elements received from CMM-Manager.
Medisize LabVIEW ATE v2 - An interface was added for version 2 of Medisize LabView ATE.
General QC-CALC - Only settings that have been changed are being written to the INI files now.
QC-CALC SPC - Fixed an error that appeared when Monitoring a file on the network and the network connection was lost.
SmartReport - Automatic Reporting and Exporting were not enabled when using SmartReport mode.
General QC-CALC - Fixed a problem with the Debug.txt and DebugSetting.txt files that happened when the files got too big and were renamed to start a new file.

QC-CALC Real-Time - The "Increase machine dimensions in file to match those in the part file" option in the Tools - Options - Data Collection - Actions area was removed.

QC-CALC Real-Time - Removed the Tools - Options - Statistical Settings - Save Calculated Limits when Finished option and changed the Stop Auto Calculating Limits option so it now saves those limits.

QC-CALC Real-Time - The Part Rate option that appeared in the Bottom Status Bar was removed.
Reporting - The "None" option is no longer available in the Report - Print Report list of Report Types.

3.4.6011/6/2014
Renishaw Ballbar20 Output (B5r) - Added an interface for the Renishaw Ballbar20 Output (B5r).
Dimension Filtering - Improved the Dimension Filtering area so the Advanced button on the Choose from List screen is no longer needed and the Containing Text functionality now automatically saves under a generic name like the Choose from List screen does.

Admin Tool - Fixed a problem caused by having a space at the end of the name of an Admin User Group.
QC-CALC Real-Time - There were times the File area in the Set up Trend Detection - Report and Log area was grayed out. This should no longer happen.
QC-CALC SPC - Improved the speed of loading the Grid View in QC-CALC SPC and at the same time improved the reaction time when scrolling through the grid when a larger .qcc file is open.

SPC Reporting - Made some improvements when generating a report on a Group where there was a different number of records in each file.
QC-CALC SPC - Stopped an error from happening when Monitoring a file across the network and the network connection was lost.

3.4.5910/29/2014
Geomagic Control 2014 (xml output) - Added Geomagic Control 2014 as a new machine driver.
QVI Zone3 - More changes were made to the Zone3 interface.
Hexagon Quindos - The option within Quindos for not allowing a negative nominal is now handled correctly.
QC-CALC Real-Time - Configuration files from the Setup folder were not being copied correctly for certain machine types.

3.4.5810/16/2014
QVI Zone3 - Added an interface for the QVI Zone3 software.

3.4.5710/13/2014
Hexagon Quindos 7 - Added logic to the Quindos 7 driver to deal with the nominal not being allowed to be negative.
General QC-CALC - Sigma by R, Cpk, and Cp are now available when the Subgroup Size = 1 and the MRbar/D2 calculation is now being used to calculate Sigma in this case.
QC-CALC Real-Time - The GR&R ANOVA calculations have been changed to match the MSA Third and Fourth editions.
Exporting - The Define Out of Spec as an Invalid Measurement (K0002 290) option in the Q-DAS Format ASCII File Default Export configuration area is now being remembered and used correctly for all new .qcc files.


3.4.5610/6/2014
Keyence CSV Network - A new Keyence CSV Network interface was added. This uses the same Keyence CSV driver, but the name of the QCC file will be based on the name of the folder where the csv file was found and it will also searches sub-folders.

Automatic Reporting - It is now possible to use the ADOBE PDF Format Signed option for the Print to File choice from the Automatic Reporting screen too. Previously this was not available because it can stop the data collection process until someone enters their user name and password.

Nikon CMM-Manager - The Nikon CMM-Manager driver was improved so single-sided dimensions are now handled better.

3.4.5510/1/2014
MicroVu InSpec - The MicroVu InSpec driver was improved so commas can now be included in Feature Labels without issue.
Exporting - The user is now warned if there are non-numeric values in the Dimension Source or Dimension Information areas when trying to export to Net-Inspect Web Export.

Data Collection - QC-CALC Real-Time was changed to accept the new Synchronize settings for Dimension Filters coming from QC-Gage.

General QC-CALC - Fixed the Help - Run Update menu functionality so it works correctly in Windows 8.
Q-DAS Export - A K-Field value is now only included in the export once. Previously it was possible to have the same K-Field included automatically and also create a customized one of the same number.

Exporting - Fixed a problem with Deleted Points not being reported correctly in the SPC Office Buddy export.
General QC-CALC - Made an additional improvement so QC-CALC works correctly when using DFS (Distributed File System).

3.4.549/22/2014
General QC-CALC - Fixed a problem in the previous revision that caused the Database Settings tab in File - Modify Database Structure area to be blank.


3.4.539/19/2014
Cummins Test Stand - Added a Cummins Test Stand interface.
Stresstech ViewScan - A second Stresstech ViewScan interface was added to handle a more expanded output file.
Nikon CMM-Manager - Added the ability to use the Note as the Feature Label in the CMM-Manager interface.
Data Collection - Changed the Text Factor having name - MultiSource Record Merge Method so wildcard characters (*, #, ?) can now be used in the Text Factor Label.

Exporting - Fixed the Range of Records choice for Manual Exporting so choices other than All Displayed and Newest Records in File now work.

Data Collection - The Unique Factor (Auto detect. Use Measure order if no unique Factor) option was removed from the MultiSource Record Merge Method list.

Manual Input - The Manual Input screen will now appear when using SmartReport.
Data Collection - Fixed a problem that caused the source files for some machine types not to be copied into the c:\Prolink\QC-CALC 3.4\ArchivedMachineData\Backup\ folder.


3.4.529/11/2014
General QC-CALC - Fixed an issue with licensing when using the silent install.

3.4.519/9/2014
General QC-CALC - The new Themes (Tools - Options - Global area) functionality was added to change the look and feel of the screens.

QC-CALC SPC - You are now able to open a Group of QC-CALC files by using a command line option from a batch file.
Hexagon Quindos - Changed the Hexagon Quindos driver so the Element name can be used for the Feature Label.
QC-CALC SPC - Interface improvements were made to the Group - Edit Group window.
QC-CALC SPC - Fixed a problem that happened when opening a Group of multiple .qcc file and assigning different Record Filters to each file. When the Group or QC-CALC SPC was closed and reopened, the Record Filters were not applied correctly.

Exporting - Fixed an issue with saving the configuration settings for an Export to SPC Office Buddy.
Exporting - Fixed the validation of the records to use so up to 30,000 records is now allowed for either the Automatic or the Manual Exporting.

Reporting - Fixed the validation of the records to use so up to 30,000 records is now allowed for either the Automatic or the Manual Reporting.


3.4.508/26/2014
Data Collection - Fixed an issue where the Manual Dimension values within a record in a MultiSource file were being set to 0 and marked as deleted when any source for that record was received.

3.4.498/22/2014
GE AFDA - Added an interface for GE AFDA's file format that can be used a primary data source or as a second source for CMMs.
Record Filtering - Fixed some messages that appeared when attempting to apply a Record Filter to a file that didn't have the correct Factor location.

3.4.488/15/2014
Tinius Olsen HSK-S - The Tinius Olsen HSK-S interface was added.
Exporting - Becker Quality Solutions Reaction Plan Manager ++ was added to the list of Export Types.
General QC-CALC - Made an improvement so the creation of a new .qcc file works correctly when using DFS (Distributed File System).
OGP/QVI MeasureMind and MeasureX - A PathSwitch can now be added from the Header area instead of only from User Inputs or Math statements.
Reporting & Exporting - A new Report and Export Type of "None" was added to the Automatic Reporting and Exporting areas so that you can now report/export for some .qcc files and not for others.

Keyence (all formats) - The actual value being received as "FAIL" is now handled by all Keyence interfaces.
Air Gage Gage Master - The Air Gage Gage Master interface now has a configuration file to use for settings.
General QC-CALC - The Help - Gather QC-CALC Information menu operation was improved.
QC-CALC Real-Time - Short-Term Sigma, Cp, and Cpk are now available as the calculation in the graphs and in the Raw Data report.
General QC-CALC - Fixed an issue in many areas in the program so characters in unicode languages will be displayed correctly.
Hommel OpticLine - Fixed a problem in the Hommel OpticLine driver where the Text Factors were not being recorded correctly.
MicroVu InSpec - The MicroVu driver had previously assumed that all Feature Labels being received had colons. This was not true and was causing Feature Labels without colons to not be collected.

Exporting - The Export Data Now menu was fixed.
General QC-CALC - QC-Config (Shift + F8) was improved so badly formed INI files are handled better and QC-Config no longer attempts to read from the registry.

3.4.477/11/2014
QC-CALC Real-Time - Any changes made to settings within QC-CALC Real-Time are now logged to a file for support purposes.

Reporting - Data Notes are now available within the Raw Data reports and a new template is being shipped to display these values.

Nikon CMM Manager - Nikon CMM Manager now handles more than one part in the same file.
QC-CALC Real-Time - Two new options were added to the Tools - Options - Miscellaneous area to control how the manual Report and Export settings work. The two options are to have the settings apply to the .qcc file open at that time or to always have the settings apply regardless of what .qcc file is open.

Manual Input - Overall the Manual Input screen was improved to make the usage during data collection flow better. At the same time, an option was added to Remember the last Factor value entered and display it again the next time the screen is shown.

MicroVu InSpec - Changed the MicroVu InSpec driver to handle copied features and copied parts so unique labels and separate parts are maintained.

Exporting - Fixed the Excel/Access exporting so you can now skip the Fails column without the Factor values ending up in the wrong columns.

QC-CALC SPC - Fixed a problem in QC-CALC SPC where the name of the previous .qcc file that was open was sent to the Report - Stat Summary report instead of the currently open file name being sent.

General QC-CALC - Fixed a problem that happened if a Calculated Dimension had a really long calculation changed to be a shorter calculation.

Exporting - The Secondary Export was made to work again.
QC-CALC Real-Time - The menus to enable Automatic Reporting and Exporting are now controlled correctly by the Administrative Tool.
Exporting - The option to add an underscore (_) before the Excel sheet name instead of replacing the first character with an underscore is now working.

QC-CALC Real-Time - Fixed an issue where a newly added (adapted) dimension was being displayed in the wrong order.

SPC Reporting - Fixed an error when you tried to email a report in QC-CALC SPC (not the Report - Other Reports menu) by using the SMTP method.


3.4.466/13/2014
General QC-CALC - Fixed an issue in the previous revision that was caused by having a non-period decimal delimiter on the computer.
QC-CALC SPC - Fixed a problem that was causing problems on Windows XP computers at times.
General QC-CALC - Made a change so computers that require FIPS compatible encryption are now able to run QC-CALC without errors.

3.4.456/5/2014
Laser Tracker - Laser Tracker now reads the three formats produced by that gage: GD&T, SurfaceDeviation, and CurveDeviation.
Werth Multi-Sensor CMM Version 8 - A new interface was added for Werth Multi-Sensor CMM Version 8.
Gleason Gear Checker - Added a new interface for the Gleason Gear Checker software.
Mahr MarSurf XR 20 - Added a new interface for the Mahr MarSurf XR 20 software.
General QC-CALC - Read/Write access to the Registry is no longer required for this application to run.
Etamic Gages CMZ32 & CMZ16 - The override "Etamic_Append_Number_To_Label" was added to change the labels of current users from "FeatA_123" to "FeatA". Also, the three-digit ID number is being removed from the feature label and is now stored in the Dimension_Info area.

Q-DAS - The Q-DAS interface now collects Text Factors from several more K-Fields.
Record Filtering - Added an option that limits how many records a filter will search in order to speed up processing.
Reporting - The Visual Part Report now has User Inputs and the Report Notes available for display.
Reporting - The Multi-Piece First Article report now has all Factor values available in the table and an override was added to control the number of parts sent to the report overall.

Exporting - Added Number of Fails to the SPC Office Buddy export. This is calculated based on the actual dimensions sent and not the Number of Fails column that is associated with all dimensions.

SPC Reporting - Detecting the utility used to digitally sign PDF reports was improved to stop a couple errors from happening in QC-CALC SPC on specific computers.

Data Collection - Fixed a slow down that happened during data collection.
General QC-CALC - Improvements were made in the File - Modify Database Structure area when making a circular file non-circular. This was made to stop errors from happening within EDL.

QC-CALC Real-Time - Improved the wording and options in the Frequency screens for both Automatic Reporting and Exporting.

QC-CALC Real-Time - The Automatic Factors from the Tools - Options - Factors area are now working correctly.
QC-CALC Real-Time - The Archiving functionality was fixed so the flag for a Deleted Point is now also saved to the archive file.

3.4.445/8/2014
PANalytical Axios XRF Spectrometer - Added a new interface for PANalytical Axios XRF Spectrometer.
General QC-CALC - Improved the installation process so running the first time when not logged in as an Admin will no longer have issues.

Exporting - Added the ability to Match features on "Feature Number", "Feature Label", or the "Extra Info" area for the Net-Inspect Web Export.

Admin Tool - When using the Auditing (Part 11) functionality the File - Compact Database menu is now disabled.

QC-CALC Real-Time - Fixed a problem where the Machine Type chosen during the evaluation period ends up stuck when GageStation is licensed.

Data Collection - Fixed an issue that happened when using a Circular Database with multiple sources and the data would be saved into the wrong records.

QC-CALC Real-Time - The Force default Export/Report settings for all parts options in the Tools - Options - Defaults-Auto Export/Report areas were not being saved correctly.


3.4.434/25/2014
Metris Camio (Custom M Files) - Made a change to the Metris Camio (Custom M Files) driver.
Exporting - With the WinSPC export the part and plan can now be blank and the name of the QCC file will be used instead.
Exporting - Fixed an issue where the Export settings for some Export Types were not being save correctly.
LK CMM using LK-DMIS, Metris LK Camio, Renishaw Modus, Renishaw Modus Equator - A "Point-Profil" feature can now be negative in the RES files.
Exporting - The interface for WinSPC has been updated to handle the WinSPC 8.2 version.
Admin Tool - Fixed an issue where Model Codes were being save in the Admin Tool area and joining a User Group caused the Model Code from that User Group to be inherited.

3.4.424/17/2014
Exporting - Checking the entered file extension for the Export - File Name value has been improved.
Reporting - Checking the entered file extension for the Report - Print to - File - File Name value has been improved.
Reporting - Fixed an error the appeared when running the Visual Part Report with more than 100 records.
General QC-CALC - Fixed an issue with sending dates to the EDL program to store in SQL.
Data Collection - The Remeasure using MultiSource (based on a matching Factor value) was not removing the Deleted flag in some cases.
Data Collection - When a new value is received the Deleted flag is removed regardless of if the point had been received previously or if it had been marked as Deleted manually.

3.4.414/3/2014
Exporting - Fixed an issue where the export wouldn't trigger if not all dimensions had been received.
Reporting - Fixed an issue where the wrong records would appear in the report if not all dimensions had been received and the Range of Records was set to Newest in File.

Reporting - Fixed an error that appeared if you tried to use the Design Template option for the Raw Data report and the .qcc file in use at that time contained more than 30 dimensions.

QC-CALC SPC - The Out of Spec coloring for True Position values in the grid in QC-CALC SPC now takes the Bonus value into account.

3.4.403/28/2014
General QC-CALC - The interface for the Prolink License Server was added.
Reporting - The Stat Summary report was improved to include the Bonus Tolerance on True Position features when calculating the Out of Specification values.
General QC-CALC - Any errors that are shown in the Status area or the new error handling screen are now also written to the ErrorLog.txt file and retrieved by the Help - Gather QC-CALC Information process.

QC-CALC Real-Time - The Tools - Set All ‘Prevent Tolerance Update’ and Clear All ‘Prevent Tolerance Update’ menus were removed since that functionality is now covered by the File - Edit Nominals and Tolerances screen.

QC-CALC Real-Time - The Archiving menus were removed from the Tools menu because the interface in Tools - Options - Data Collection - Set Paths covers the same functionality.

QC-CALC Real-Time - Made the Email Properties screen from the Trend Analysis setup area appear on top of the other forms when Always-On-Top is enabled.
CFR Part 11 Audit Report - The Include Creation Entries option is now remembered and used when printing the Audit Report.
Reporting - Detecting the utility used to digitally sign PDF reports was improved to stop a couple errors from happening on specific computers.

3.4.393/20/2014
QC-CALC Real-Time - Unchecking the Use default Trend Detection settings option was causing an error.

3.4.383/18/2014
Reporting - Added Factors to the list of variables for the Visual Part Report.
Reporting - A new flag is being sent to the Raw Data report to signal each point being out of specification. Also, the Raw Data, First Article, and MultiPiece First Article reports now apply the bonus to True Position features when deciding the out of spec status.

Trend Detection - When the Use default Trend Detection settings option is unchecked for an individual .qcc file, the Tools - Options - Defaults - Trend Detection settings are now shown on the screen.

Automatic Reporting - When the Use default Report settings option is unchecked for an individual .qcc file, the Tools - Options - Defaults - Auto Report settings are now shown on the screen.

Automatic Exporting - When the Use default Export settings option is unchecked for an individual .qcc file, the Tools - Options - Defaults - Auto Export settings are now shown on the screen.

Manual Input - When the Use default Manual Input settings option is unchecked for an individual .qcc file, the Tools - Options - Defaults - Manual Input settings are now shown on the screen.

Reporting - Fixed the Number_of_Points value in the Visual Part Report so it will have a value.
Reporting - Fixed a problem when running a Stat Summary or Plot Report in SPC and a Group was open.
Reporting - Fixed the Number_of_Records value in the Plot Report so it is now taking the visibility of Deleted Points into account correctly.

Exporting - Fixed an issue where the configurations for certain Export Types were not being saved correctly.
QC-CALC Real-Time - Stopped an error that happened when choosing certain machine types from the Help - Install Wizard screen.

Admin Tool - Stopped the error that was happening on the Part 11 settings screen when switching off the Users tab and LDAP was enabled.
General QC-CALC - Fixed a problem that happened when choosing Recalculate All Points in View or Recalculated Dimensions for Selected Points from a right-click and the calculation was too long.

Record Filtering - Stopped an error from happening when the Record Filter being applied had extra parenthesis surrounding an ASK-VALUE option.
Exporting - When Exporting to an SPC Office Buddy Excel Job, the temporary .qcc file that is created now has the correct Precision for each dimension in the file.

3.4.372/26/2014
General QC-CALC - Fixed a problem where changes that were made to Factor values were not reflected in the SQL database being synced using EDL.
Metris LK Camio, Renishaw Modus, Renishaw Modus Equator - A minor change was made to the driver for the Metris LK Camio, Renishaw Modus, and Renishaw Modus Equator machines. The driver can now handle a missing blank line between the factors and dimensions in the CSV file.

Hexagon Quindos 6 - Improved the Quindos 6 driver to handle slightly different output.
QC-CALC Real-Time - Fixed a error that happened when QC-CALC found the command file from QC-Gage and attempted to process it, but the file was still being held open by QC-Gage.


3.4.361/31/2014
Zygo MetroScope - A new interface was added for Zygo MetroScope.
Marposs Gage E9066 - A new interface was added for Marposs Gage E9066.
Nikon CMM-Manager - Changed the Nikon CMM-Manager interface to handle the UTF-8 format files that are now being created.
Instron Bluehill Tension - More improvements were made to the Instron Bluehill Tension interface.
Exporting - Added Net-Inspect's HTTPS interface.
Mitutoyo FormPak - The Mitutoyo FormPak interface was improved so data would be collected if there are more items sent in the communication file than previously expected. The Serial Number value is now being stored in a Text Factor too.

Mitutoyo MCOSMOS - There are now more format choices for Custom Labels for the Mitutoyo MCOSMOS interface.
Exporting - Fixed an issue that was found with the Becker Quality Solutions (Reaction Plan Manager) export.

3.4.351/28/2014
Dimension Filtering - When using the Containing Text Dimension Filter it is now possible to filter based on Dimension Information and Dimension Source values. Searching for values "Beginning with" and "Ending with" was added at the same time.

Exporting - Added Becker Quality Soltions (Bolt Pattern Analysis) to the list of Export Types.
QC-CALC SPC - Added an override to turn off the Part Rate Monitor in QC-CALC SPC.
Q-DAS Export - Added a option to the Q-DAS Setup page for exporting which allows the user to change the definition of the K0002 Attribute tag.
General QC-CALC - All of the copying of files now handles hidden files.
QC-CALC Real-Time - Fixed an issue where some of the Automatic Reporting and Automatic Exporting settings were being used across all parts regardless of the Use default settings option.

Reporting - Fixed the Plot Report settings for Display Record Numbers, Display Record Dates and Times, and Do not display deleted points options so they are saved and used correctly.

Admin Tool - The screen validation was improved in the Part 11 area so you are no longer able to move from tab to tab with the Enable Auditing option checked if you do not have at least one User or Reason Code entered.

3.4.341/10/2014
Zeiss ACCTee Pro (Contour, RondCom, and SurfCom) - Added Zeiss AccTee Pro drivers for Surfcom, RondCom, and Contour.
Renishaw Modus Equator - Added Renishaw Modus Equator hooks to use their Compare mode. QC-CALC now creates different files depending on how the machine is running - Measure, Master, or Calibrate.

General QC-CALC - Made a few improvements to make messages not in English appear better on the screens and also changed some screens to use messages that had already been translated.

QC-CALC Licensing - Improved the message that appears when the Kill License button is used so the user is aware they need to contact Prolink to finish the process.

Instron Bluehill Tension - Instron Bluehill now names the QC-CALC database after the CPN value which is the first line inside the communication file.
GR&R - Fixed an issue with the GR&R calculations for MSA 3. As of this version the equation changed slightly because they use different K1, K2, and K3 constants. In addition, they divide the spec spread by 6.

Manual Input - The Manual Input Setup screen was not creating Factor Lists correctly.

3.4.3312/6/2013
Record Filtering - Removed Global Default button from Record Filter screen.
Record Filtering - Fixed an issue with the Record Filters caused in the previous revision.

3.4.3212/2/2013
Data Collection - Fixed a problem that slowed down data collection when saving the data across the network. Also sped up how quickly the Status Area appears when processing a larger file (or multiple files) from the inspection machine.

3.4.3111/26/2013
ASI Datamyte Transend - Fixed the ASI Datamyte Transend driver to allow the translation of the date field in the header. ASI translates their headers into the local language so the customer will have to override the word "date".

Q-DAS Export - Changed the Q-DAS .dfx output so the Date and Time values are guaranteed to have a slash (/) as the separator between the values regardless of the date format of the computer in use.

Exporting - Fixed exporting to IQS so the Records Received Since Last Export option works correctly now.
Renishaw Modus Equator (RES files) - The Renishaw Modus Equator (RES files) interface now correctly collects profiles.

3.4.3011/15/2013
Zeiss ACCTee Gage - The Zeiss ACCTee Gage interface was added.
PC-DMIS (All supported versions) - An override was added which allows you to specify the delimiter used between the feature and characteristic names when the final Dimension Label is being created during data collection.

Z-Mike Model 4025 & 4050 - The Z-Mike driver was changed to handle the minus sign not being included with the Minus Tolerance value.
Instron Bluehill Tension - The Instron BlueHill Tension driver now collects a text factor correctly.

3.4.2911/1/2013
Keyence CSV IM Format - A new interface was added to handle the CSV format from the Keyence IM Series machine. This format is very similar to the serial format used for the Keyence IM Series driver, but the data is received in a file instead of via the RS232 port.

Keyence CSV IM Format - The Keyence CSV IM format now handles spaces in all labels and values and a Text Factor was added with OK or NG description for part.
MT Gage or EasyCheck by PQI - Changed name of the interface to "MT Gage or EasyCheck by PQI" to reflect the current "MT Gage" name of the program.
Manual Entry Screen - Made some improvements in the Manual Entry Screen area so the screen will work better with the changes made in the 3.4 version.

3.4.2810/7/2013
Data Collection - Added ReplaceFeatureLabelsWithExtraInfoFields flag which allows you to replace the feature label of each feature with the extra info field if it is available. If not available it is ignored. In addition, added ReplaceFeatureLabelsWithExtraInfoFieldsStartChar override which allows you to specify a starting character string so that only extra info fields with the starting character string will actually replace the feature labels. The rest are ignored. If left blank, all feature labels are replaced. Typically this would be something like *** but allows users to enter normal extra info such as critical flags without replacing all feature labels. If replacement is made, the starting char. string is removed from the feature label. Good for creating duplicate features in gage without actually doing so in the labels.

Stresstech ViewScan - Added an interface for Stresstech ViewScan.
Xspect OpenDMIS - Added an interface to a newer format of OpenDMIS.
Approve for DeMeet Multi-sensor - The Approve for DeMeet Multi-sensor machine interface has been added.
Keyence CSV - The Keyence CSV machine interface has been added.
Kapp Stock Removal - The Kapp Stock Removal machine interface has been added.
Laser Tracker - Added an interface for Laser Tracker from BuildIT.
Metris Camio (Custom M files) - The interface for Camio Custom .M files was added.
VISIONx - The VisionX machine interface was added.
MetLogix - Added an interface for MetLogix's M2 and M3 software.
Exporting - Updated the Net-Inspect web sending due to changes on the Net-inspect side.
Exporting - The Open in Default Application option is now enabled in the Manual Exporting area for Export Types that can use it.
Etamic Gages CMZ32 & CMZ16 - Added a new override (Etamic_Use_Tolerances_NOT_Specs) that makes the driver assume the incoming values are tolerances and not specifications when the value is set to 1.

Etamic Gages CMZ32 & CMZ16 - The DS (Dimension Source) value being received from the Etamic Gages interface is the same across all features, but can change with each part. This is now being stored in a Text Factor in order to track these changes on a part by part basis.

Nikon CMM-Manager - Added an override for the Nikon CMM-Manager interface that defines which header item is used as the QCC file name and improved the interface to handle single-sided tolerances better.

Metris LK Camio (RES files), LK CMM using LK-DMIS (RES files), Renishaw Modus (RES files), Renishaw Modus Equator (RES files) - Minor changes were made to these drivers to pick up some additional Line-Profile items.

Mitutoyo MCOSMOS - Added an option for reading values for Concentricity so the deviation is used as the actual value.
Exporting - Fixed an issue with the export path in Becker Quality Solutions export. It was not being set unless the Configure button was pressed.
Data Collection - Fixed an error that occurred when QC-Gage was sending data to QC-CALC Real-Time.
General QC-CALC - Fixed a problem that happened during start up and shut down when Windows was not deleting a folder fast enough.
General QC-CALC - Fixed an error that occurred when reordering Dimensions by using the File - Modify Database Structure menu.
QC-CALC Real-Time - Fixed an issue where the Source File Path and Name area did not allow the file name portion to contain a wild card.
Mitutoyo RoundPak - Fixed the Mitutoyo RoundPak driver to handle the newer software version and files containing multiple runs.
Dukin NeuroMeasure 5 - Fixed the Dukin NeuroMeasure driver to read the headers correctly and to use one of the headers for the file name since their output file names are all different.

Sheffield MeasureMax (CSV files) - The Sheffield MeasureMax (CSV files) interface is now specifically shown in the list of available Machine Interfaces.
General QC-CALC - The Reset Password functionality for both the Admin Tool and the Password Protection area has been fixed.

3.4.279/24/2013
General QC-CALC - The label on the Range Chart in QC-CALC Real-Time and the Plot View of QC-CALC SPC now says "Moving Range Chart" when the Subgroup Size = 1.
SJ Inno-Tech Screen Printer - Changed the SJ Inno-Tech Screen Printer driver to allow the filename to be passed in.
QVI Vici MTL - Adapted the interface for Vici MTL so French words can be used in the output file and the data will still be collected.
Exporting - The Dimensions As Rows option used for Excel exporting did not export any data at all.
Automatic Exporting - Using the Export Data Now menu when exporting automatically to Minitab was only exporting a single record regardless of the number of records that should have been sent.

QC-CALC SPC - Fixed an error that appeared when starting QC-CALC SPC and the selected Dimension Filter was not found.
Data Collection - When collecting data into a file with multiple sources it was possible for a second source to be written into a deleted record. This would undelete the record and make the values from the first source active again.

Automatic Reporting - The email settings in the Tools - Options - Defaults - Auto Report area were not being remembered or used for new files.
General QC-CALC - The Tools - Password - Lock Menus functionality has been fixed and menus not visible are no longer shown in the list.
Data Collection - The Discard new data option used when QC-CALC receives a different number of dimensions than expected is now working again.
Admin Tool - You are no longer allowed to change tabs within the Part 11 settings section of the Admin Tool if there is an invalid path on the tab you are leaving.
Data Collection - Fixed an error that appeared when using the Unique Factor (Auto detect. Ask operator) method for a MultiSource file.
Trend Analysis - A First Article Report triggered by a trend was displaying the left-most data point instead of the data point that actually triggered the trend.
Exporting - The output date in the JMP export was using the date from the first record of the .qcc file instead of the record being exported.

3.4.269/3/2013
General QC-CALC - Changed the messages that appear when an error happens so they are easier to understand and email.
Data Collection - A new override has been added to remove any balloon characters from Factor Labels if the overrides for the Feature Labels are in use.
Renishaw Modus Equator - The Renishaw Modus Equator interface was finished.
Nikon CMM-Manager - Added an option for Nikon CMM-Manager to use the Notes field as a label when defining a USER_Defined feature.
Keyence IM Series - Added an option for the Keyence IM Series that allows parts from separate communication files to be combined into one record in a .qcc file.
QC-CALC Real-Time - Fixed an issue that happened occasionally when a Tool Tip was triggered when it shouldn't have been available.
Exporting - The new option for naming Excel sheets was changed to default to the way it used to work before the option was added.
Manual Entry Screen - Fixed the Manual Entry Report so it works in this version now.
Reporting - Choosing the Print Setup button will now automatically choose the Use selected printer option. Cancelling from the Print Setup screen is now handled correctly too.

Reporting - The Print To... - File - File Name is now validated before leaving the screen so invalid characters cannot be used.
General QC-CALC - A few paths/file names in the software are now being checked for validity before being saved.
QC-CALC Real-Time - Removal of the View - Basic|Advanced|Custom menus was completed.

3.4.258/15/2013
General QC-CALC - Updated some email settings to match with Prolink's default server.
Exporting - The list of illegal characters that cannot be used in sheet names was updated to include "+". Also, added an Excel exporting option to handle sheet names starting with a numeric character. Excel does not allow this, so the choices are to replace the first character with an underscore or to pre-pend an underscore before the first character.

QC-CALC SPC - Added an override that gives control over how often the files are checked for changes when using the Monitoring option.
QC-CALC Real-Time - The INI Recovery functionality that was already in place was brought into QC-CALC Real-Time too.
General QC-CALC - An option was added for both QC-CALC Real-Time and QC-CALC SPC to control the Feature Labels displayed on the Plots. You now have the option of viewing just the Feature Labels or adding/replacing the Dimension Information field too.

Reporting - The Stat Summary report within QC-CALC Real-Time did not have the Subgroup Size value set correctly, so calculations using the "by Range" method (Sigma by Range, Cpk by Range, ...) were not correct. The summation calculation for sigma was being used instead in these cases.

Exporting - When using the Export to SPC Office Buddy option the Notes are now sent over along with the data.
QC-CALC Real-Time - Two choices were missing from the Tools - Options - Defaults - File Creation - MultiSource and have now been added to the MultiSource Record Merge Method list.

Reporting - The Selected Points option was put back into the list in the Range of Records area of the Manual Report Settings screen.
QC-CALC Real-Time - The "2 Sigma" label was previously white text on a yellow background and not easy to read. The text color has been changed to always contrast well with the color chosen for the 2 sigma zone background.

3.4.247/19/2013
Hommel Etamic Form Tester - The Hommel Etamic Form Tester has been added to the machine interface list.
QC-CALC SPC - Fixed an issue that happened when QC-CALC SPC was launching and attempting to delete a folder that didn't exist.

3.4.237/17/2013
QC-CALC SPC - Grid View now displays the Last Written Record when the file is opened instead of displaying the first record in the file.
Metris Camio (Custom M files) - Made slight changes to the new custom Camio Interface.
General QC-CALC - When upgrading from an older version the Assignable Cause and Corrective Action files were not brought across if the default files were still being used in the old version. That has been fixed.

Manual Input - When setting up the defaults to use in a new .qcc file for the Manual Input screen the Text Factors, Numeric Factors, and Manual Dimensions that exist in the currently open .qcc file no longer impact the items available to use within the setup area.

Exporting - The Append option is now available for the correct Export Types.
Exporting - Fixed a error that happened when data was exported after the number of dimensions in the file increased.
General QC-CALC - The "(Editing Locked)" caption in the Point and Plot Properties panels now reflects the state of the File - Lock Editing in Point and Plot Properties menu.

General QC-CALC - Fixed an issue where some settings were not being applied after they were changed. A restart of the software was required to get the setting applied.

QC-CALC Real-Time - Fixed a problem that happened when trying to use the Tools - Options screen with no .qcc file open.
Record Filtering - Any applied Record Filter is shut off if the file containing that filter is not found for any reason.
QC-CALC Real-Time - Fixed a few of the new forms that ended up underneath the main form when Always-On-Top is enabled.
General QC-CALC - A few locations within QC-CALC were not connecting to paths correctly when UNC paths were being used.
QC-CALC SPC - Record Filters were being reapplied when moving from plot to plot while using Plot View in QC-CALC SPC. This was causing a slowness in QC-CALC SPC that has now been fixed.

3.4.227/3/2013
Metris Camio (Custom M files) - Added a custom Camio interface to read .M files.

3.4.216/28/2013
SJ Inno Tech PCB - Added an interface for the SJ Inno Tech PCB screen printer.
OGP MeasureX - Changed the OGP and SmartReport drivers so MeasureX always uses regional settings when reading the Date instead of reading the Date Format from their settings that is not really used.

Exporting - The export to SPC Office Buddy was not populating the Dimension Information and Dimension Source areas.

3.4.206/19/2013
Exporting - Fixed an issue in the Net-Inspect web export.

3.4.196/14/2013
Exporting - Added Net-Inspect web export type to allow users to upload their data directly to the Net-Inspect website from QC-CALC Real-Time.
General QC-CALC - More licensing changes were made.

3.4.186/11/2013
Reporting - The Raw Data report was updated to make consistent variable and field names. All default templates were updated to reflect these changes.
Exporting - When selecting a new Export Type you are now prompted immediately for both the Path and File Names and the correct file extension is automatically added to the file name.

General QC-CALC - The Tools - Options - Assignable Cause /Action area no longer allows the same file to be chosen for both options.
Nikon CMM-Manager - There are times when there are two Feature records in a row received from Nikon CMM-Manager and when this happens they are now joined with an underscore.

PC-DMIS 4.0+ by Wilcox Associates - True Position features in PC-DMIS now ignore the bonus that is passed in and save the Plus Tolerance instead.
MetLogix - Improved the interface for MetLogix's M2 and M3 software.
SmartReport - The Export Types used within the QVI software are now balanced with the Export Types available within QC-CALC Real-Time.
Manual Input - It is now possible to disable the option for checking values as they are typed into the Manual Input screen to verify they are within a certain percentage of the tolerance for that item. Also, only Manual Dimensions that exist in the .qcc file are available to be used in the Manual Input Setup area.

General QC-CALC - Added new licensing options.
Reporting - Fixed an error that happened when running a Plot Report on a file that has True Position plots shown.
Exporting - Using the Selected Points option in manual Exporting exported all records instead of just the ones that were selected.
Exporting - When exporting all dimensions were being exported regardless of the Dimensions to Export setting.
Exporting - The wrong records were being exported when there was a circular database in use and N Newest Records in File option was used.
General QC-CALC - The program no longer asks if you want to copy settings from QC-CALC 3.2 when the 3.2 version hadn't been installed.
General QC-CALC - Fixed an issue where changes made in the Tools - Options screen were not available immediately after leaving the screen.
Admin Tool - Locking down the Dimension Filter area was undone by opening a different .qcc file.
QC-CALC SPC - The Fail Count displayed in the Grid View screen now takes the Bonus Tolerance into consideration for True Position features.
QC-CALC SPC - Fixed an error that appeared when running an Xbar & Range report with a Group open.
QC-CALC SPC - When QC-CALC SPC is launched from the File - Show QC-CALC SPC menu within QC-CALC Real-Time (or the corresponding Toolbar button) the file QC-CALC Real-Time had opened will automatically be opened in QC-CALC SPC too.

Manual Input - Checking for Required values and if a value is within a certain percentage of tolerance is only performed on items that are visible in the Manual Input screen. The Tab and Enter keys now move the cursor to the next available cell and items entered into the Manual Input Setup screen are now validated consistently.


3.4.175/8/2013
Exporting - Fixed an issue where all files being created by the Manual Export operation were being created in the QC-CALC 3.4\Data folder instead of the folder specified.

GageStation - Changed the source File Path and Name for GageStation to reflect the new 3.4 version of QC-Gage being used.

3.4.165/2/2013
MetLogix - Added an interface for MetLogix's M2 and M3 software.
PC-DMIS Exact Measure - Added new CTNs and DTNs to the PC-DMIS Exact Measure driver and fixed a couple issues in the xml parsing.
Instron Bluehill - Updated the Instron Bluehill driver to match the output now being produced.

3.4.154/30/2013
Record Filtering - Fixed a problem that was found with the records that were returned from the Record Filter.
Exporting - The Export - Export Data - Range of Records - All Available Records option was fixed.

3.4.144/26/2013
General - The filename used during the Help - Run Update process was updated to the 3.4 version level.

3.4.134/26/2013
*** OFFICIAL RELEASE***